Baylis radiofrequency pain treatment system

Baylis radiofrequency pain treatment system is the only digital radiofrequency pain treatment system based on computer platform in the world, and it is also the radiofrequency pain treatment system with the most operation modes in the world.

+
  • picture1123213.png

Bipolar / multistage RF mode

Multi channel RF technology bipolar RF technology unipolar RF damage area Dr.MatthewKline On the basis of the invention, Baylis RF uses special bipolar software to equalize the temperature of bipolar tissue, instead of the traditional positive and negative electrodes (a movable electrode, Baylis radio frequency real-time detection of bipolar temperature, real-time temperature compensation (detection and compensation in 1s) at the same time using two electrodes and cannula of the same model, bipolar radio frequency damage process bipolar space does not exceed 5 times of the diameter of the radiofrequency trocar, 5x20 = 0.175in = 0.45cm 5x21 = 0.16in = 0.41cm four pin continuous RF damage area The four pole continuous RF mode RF output power value is the output power of all electrodes and the quadrupole continuous RF mode host can display and monitor the treatment temperature of four groups of electrode needles at the same time, and the host can display the heating chart of four groups of electrode needles at the same time

message

category:

radio frequency

keyword:

electrode

产品附件:


Multi channel RF technology bipolar RF technology unipolar RF damage area Dr.MatthewKline On the basis of the invention, Baylis RF uses special bipolar software to equalize the temperature of bipolar tissue, instead of the traditional positive and negative electrodes (a movable electrode, Baylis radio frequency real-time detection of bipolar temperature, real-time temperature compensation (detection and compensation in 1s) at the same time using two electrodes and cannula of the same model, bipolar radio frequency damage process bipolar space does not exceed 5 times of the diameter of the radiofrequency trocar, 5x20 = 0.175in = 0.45cm 5x21 = 0.16in = 0.41cm four pin continuous RF damage area The four pole continuous RF mode RF output power value is the output power of all electrodes and the quadrupole continuous RF mode host can display and monitor the treatment temperature of four groups of electrode needles at the same time, and the host can display the heating chart of four groups of electrode needles at the same time

Message

Submit

Related products