Tradewind

学术文献

Academic literature

All products

It can cut and suck out nucleus pulposus efficiently, shorten the operation time. The aseptic disposable handle of nucleus pulposus removal is controlled by power supply, and the disposable handle is set faster. It does not need to clean, check and sterilize before operation. It reduces the demand for a variety of traditional instruments. The amount of nucleus pulposus removed effectively is accurate and predictable, which can reduce the pressure of nerve root No matter the patient's age and the degree of intervertebral disc hydration, it can effectively ablate the tissue. Safe cooling and fluid based cutting function eliminate the risk of tissue thermal damage. The circular and non-invasive endoresector design reduces the risk of annulus fibrosus puncture and endplate injury. The insertion depth of 0.5cm laser marking device insertion depth indicator controls the insertion depth of the device Reduce the number of times the instrument passes through the surgical site and limit the risk of accidental nerve injury
The operation time is shortened. The aseptic disposable handle is controlled by the power supply, and the disposable handle is set faster. There is no need to clean, check and sterilize before the operation. It reduces the demand for a variety of traditional instruments. The effective removal of nucleus pulposus is accurate and predictable. It can reduce the nerve root decompression. Regardless of the patient's age and the degree of intervertebral disc hydration, it can effectively ablate the tissue safely The cooling and fluid based cutting function eliminates the risk of thermal injury to tissues. The circular non-invasive endoresector design reduces the risk of annulus fibrosus puncture and endplate injury. 0.5cm laser marking device insertion depth indicator controls the insertion depth of the device, reducing the number of times the instrument passes through the surgical site, thus limiting the risk of accidental nerve injury
Fluid based cutting eliminates the risk of tissue thermal injury. The circular non-invasive endoresector design reduces the risk of annulus fibrosus puncture and endplate injury. 0.5cm laser marking device insertion depth indicator controls the insertion depth of the device, reducing the number of times the instrument passes through the surgical site, thus limiting the risk of accidental nerve injury
PRE
1
Tradewind

Department Construction

Tradewind

Academic guidance

Tradewind

Technical training

Tradewind

Product maintenance

搜索
Search

Hot Keywords: water jet, radio frequency, shock wave, mectocin

homeProductAuthoritative 丨 InformationServiceabout us

京公网安备 11010802039849号

Background line

Time of issue:2018-01-22 00:00:00